Error code reference

Victoria Arduino error codes, what they mean and how to fix them.

Victoria Arduino machines flag faults on screen as alerts and status messages rather than one universal code list, so we've grouped the common ones by the system that raises them. The notes below cover the Black Eagle Maverick and Maverick Core, Eagle One, E1 Prima, Eagle Tempo, and PureBrew+, and the older Black Eagle, White Eagle, and Adonis platforms behave much the same way. For each entry: what the machine is telling you, what's safe to try, and when to call.

★★★★★ 4.7 rating · 14 codes documented · Same-day service

Victoria Arduino code? Send it to us.

We'll get back to you today with what it likely is.

Secured with SSL. We use your information to respond to your service request and, with your permission, to send the updates above. You can unsubscribe anytime. See our Privacy Policy.

Thanks. We received your request.

A Grajqevci technician will get back to you today to confirm your machine and book the visit. If it's urgent, call us directly at (289) 217-3796.

14/14

About these codes. Compiled from Victoria Arduino product documentation and platform research, cross-checked against our own GTA service logs. On-screen wording varies by model and firmware version. Updated August 2026

Boiler

3 codes
ALL02 T3 group heating timeout Critical

One group's micro-boiler failed to reach its setpoint inside the warm-up window, so the firmware cut power to that element. The other groups usually carry on normally.

Likely causes

  • Group boiler heavily scaled
  • Heating element electrically degraded
  • Solid-state relay failed open
  • T3 calibration reset by a firmware update without recommissioning

Try this first

  1. Note which group number is flagged
  2. Confirm the other groups heat normally
When to call us

This one doesn't clear itself. We test element resistance and the relay, then recalibrate T3 through the service menu once the cause is fixed.

ALL03 Steam boiler heating timeout Critical

The steam boiler didn't reach target pressure in the time the controller allows, so it cut power to the steam element. The brew groups may still work, but steam is down.

Likely causes

  • Heating element scaled
  • Element electrically degraded
  • Solid-state relay failed open
  • Pressure stat drifted out of spec

Try this first

  1. Watch the boiler gauge from a cold start
  2. Power-cycle once
When to call us

If pressure still won't build, call us. The element and relay get tested, the circuit descaled, and the pressure stat replaced if it has drifted.

ALL05 Steam over-pressure / safety trip Critical

The steam boiler went past its safety threshold, or the safety pressure switch believes it did, and power to the element was cut. Treat it as real until proven otherwise.

Likely causes

  • Pressure stat welded closed
  • Stat drifted high
  • Solid-state relay welded on
  • Capillary tube scaled

Try this first

  1. Shut the machine down at the switch
  2. Do not restart if the gauge reads above the safe range
When to call us

Call immediately rather than restarting around it. We replace the failed stat or relay and verify the entire safety circuit before the boiler heats again.

Group head

1 code
ALL09 Pre-infusion solenoid fault Warning

The controller commanded the pre-infusion solenoid and didn't see the expected response, so pre-infusion is bypassed and shots run at full pressure from the first second. Espresso gets noticeably harsher.

Likely causes

  • Solenoid coil burnt out
  • Solenoid mechanically stuck
  • Coil wire broken at the strain relief
  • Controller output driver failed

Try this first

  1. Listen for the solenoid click at shot start
  2. Compare against a known-good group
When to call us

If the click is missing, the solenoid or its wiring has failed. We swap the coil or the full solenoid and verify the pressure curve afterwards.

Steam

1 code
ALL10 Auto-foamer / milk pathway fault Warning

On machines with an auto-foamer or auto-milk module, the milk pathway isn't delivering the foam quality or temperature the system expects, and the feedback channel has flagged it.

Likely causes

  • Milk residue in the air-intake line
  • Air-intake check valve seized
  • Milk-stone in the steam venturi
  • Worn O-rings on the auto-foamer module

Try this first

  1. Run the daily milk clean cycle
  2. Inspect the air-intake fitting
When to call us

If a proper clean cycle doesn't bring the foam back, the module needs a strip-down. We sanitize the full pathway, fit an O-ring kit, and verify foam quality before leaving.

Pump

2 codes
ALL06 Flow meter / dose timeout Warning

The controller expected flow meter pulses during a volumetric shot and saw none, so it aborted the shot. Until it's resolved, programmed doses can't be trusted.

Likely causes

  • Flow meter impeller coated with mineral deposit
  • Flow meter wiring unseated
  • Gicleur blocked on the affected group
  • Pump not running
  • Inlet water shut off

Try this first

  1. Listen for the pump engaging on a shot
  2. Try each group to isolate which one times out
When to call us

If one group keeps timing out, call. We clean the flow meter, reprogram the doses by weight, and replace the meter if the counts stay erratic.

ALL12 Pump pressure low / OPV drift Warning

Brew pressure feedback is sitting below the expected window on every group. Shots may still complete, but extraction goes inconsistent and usually tastes thin.

Likely causes

  • Rotary pump worn
  • OPV drifted away from 9 bar
  • Inlet pressure low from an undersized RO system
  • Pump capacitor degraded

Try this first

  1. Check the boiler gauge during a blank shot
  2. Confirm inlet pressure at the regulator
When to call us

If inlet pressure is fine and brew pressure still reads low, call. We reset the OPV against a portafilter gauge and replace the pump if it can't hold spec.

Electronics

2 codes
ALL11 Touchscreen / display communication fault Warning

The touchscreen has lost communication with the main controller, or the touch layer has stopped responding. The brew side may still work from manual overrides while the screen is down.

Likely causes

  • Ribbon cable unseated
  • Firmware hang after an update
  • Failed display digitizer
  • Power supply to the display out of spec

Try this first

  1. Hard power-cycle at the breaker
  2. Check whether the machine still pours from manual overrides
When to call us

If the screen stays dark or deaf after a hard reset, call. We reflash to a stable build or replace the display module, whichever the diagnosis supports.

ALL13 Lighted button bank fault Info

One or more dose buttons on a group have stopped registering presses or lighting up. The rest of the machine keeps working; it's an annoyance that grows.

Likely causes

  • Microswitch contacts corroded by steam migration
  • Failed LED
  • Ribbon to the controller unseated
  • Water intrusion behind the front panel

Try this first

  1. Test every button on the affected group
  2. Avoid wet-wiping the panel until it's been inspected
When to call us

Book it for the next convenient visit. We service the full button bank with the panel off, so it's done once instead of button by button.

Water

2 codes
ALL04 Autofill timeout Critical

The autofill solenoid ran longer than the allowed window without the level probe ever reading full, so the controller shut the fill circuit down. It's protecting you from a flood or a dry boiler.

Likely causes

  • Water supply closed or restricted
  • Softener cartridge near end of life
  • Autofill solenoid stuck closed
  • Level probe scaled
  • Internal leak

Try this first

  1. Verify the water supply is open
  2. Look inside the chassis for visible leaks
When to call us

If the supply checks out and the fault repeats, call. We descale the probe, test the solenoid, and dye-trace any suspected leak.

Maintenance Service interval / descale reminder Info

A service counter has elapsed. Nothing has failed; the machine keeps brewing and is asking for scheduled attention.

Likely causes

  • Litres-dispensed counter elapsed
  • Time-based counter elapsed
  • Water filter cartridge counter expired

Try this first

  1. Check whether the reminder is for the filter, the softener, or a descale
  2. Don't clear the reminder without doing the service behind it
When to call us

Schedule a maintenance visit at the next sensible gap in service. The counter gets reset as part of the close-out, not before.

Sensors

3 codes
ALL01 T3 boiler probe fault Critical

On T3 multi-boiler platforms like the Black Eagle and White Eagle T3 Digit, the controller has lost a valid reading from one of the boiler temperature sensors. It cuts power to that boiler's element as a precaution, so the affected circuit stops heating.

Likely causes

  • Failed NTC sensor
  • Connector unseated at the controller
  • Sensor lead damaged at a chassis pinch point
  • Steam migration into the connector housing

Try this first

  1. Power-cycle the machine at the breaker
  2. Note which boiler is flagged (brew, steam, or group number)
When to call us

If the fault returns after a power cycle, the sensor or its wiring needs proper testing. We check resistance against the reference table and swap the failed sensor.

ALL07 Gravitech load cell fault (Black Eagle Gravitech / Maverick) Warning

The Gravitech load cells under the cup platform are reporting values the controller can't reconcile with a real cup, so gravimetric dosing shuts off and the machine falls back to volumetric mode. Shots keep pouring, but by volume, not weight.

Likely causes

  • Drip tray not seated squarely
  • Vibration source under the bar (fridge compressor, loose chassis)
  • Load cell drifted
  • Load cell mechanically damaged
  • Cup overhanging the edge of the platform

Try this first

  1. Reseat the drip tray squarely
  2. Confirm the machine is level
  3. Check for vibration sources nearby
When to call us

If gravimetric mode won't come back after that, call. We calibrate the cells against reference weights and replace any cell that keeps drifting.

ALL08 NEO recovery sensor fault (Eagle One) Warning

NEO (Neuromorphic Engine Optimization) is the Eagle One's heat-recovery and power-management system. A sensor in the recovery loop is reading out of range, so NEO has dropped to standard mode: the machine still brews, it just stops saving energy.

Likely causes

  • Recovery-loop sensor failed
  • Connector unseated after a service
  • Recovery loop blocked
  • Controller relay in the NEO circuit failed

Try this first

  1. Power-cycle the machine
  2. Carry on serving; NEO is power management, not brew-critical
When to call us

Book us in when convenient rather than urgently. We read the NEO diagnostic log, test the loop sensors, and restore calibration once the failed part is replaced.

Code you can't find?

Call us with the exact display string. We'll diagnose by phone.

Free download

The Victoria Arduino cheat sheet, free

The top Victoria Arduino error codes with what each one means and what is safe to try first, plus the daily and weekly care that prevents most service calls. Print it, laminate it, tape it to the machine.

By downloading, you consent to receive occasional service tips and seasonal reminders from Grajqevci. Unsubscribe anytime, every email has a one-click link.

Trusted by Toronto's most demanding teams

You're in good company.

FAQ

Victoria Arduino error codes, frequently asked.

9 answers about resetting codes, recurring faults, firmware versions, and when DIY ends. If the recurring ones are descale or water warnings, start with the right Victoria Arduino water filter.

Updated August 2026

What does Victoria Arduino error code ALL01 mean?

Every documented Victoria Arduino fault we see is listed above, with its meaning, common causes, and what to try before calling a technician. If the code on your machine isn't on this page, call us with the exact display string and we'll work it out by phone.

Can I clear or reset a Victoria Arduino error code myself?

Sometimes. Many Victoria Arduino codes clear after a power cycle, a completed descale, or a counter reset through the service menu. Codes tied to a hardware fault (failed sensor, blown element, board issue) will return immediately and need a technician. Each code above lists what's safe to try first.

Why does the same Victoria Arduino error keep coming back?

A code that returns after a power cycle is signalling a real fault, not a glitch. The underlying part (sensor, heating element, valve, motor, board) needs replacement. Repeat codes are diagnostic gold for us, so call with the exact code and any timing or symptom pattern you've noticed.

My Victoria Arduino code isn't listed. Why?

Victoria Arduino updates fault tables across firmware revisions and model generations, and not every code is documented publicly. We see codes in the field that aren't in any published list. Call us with the exact display string and the model and we'll work it out from our service log.

How fast can you get on-site if I'm stuck on an error code?

Most calls in Toronto and the immediate GTA get same-day on-site response. Tell us the code and the model when you book and we'll bring the right parts on the first visit so the repair finishes the same day.

Do I need to be authorized by Victoria Arduino to reset an error code?

No. We're an independent service provider, not affiliated with Victoria Arduino, and we work on machines outside the manufacturer's authorized network routinely. That independence lets us service older or out-of-warranty machines authorized networks may decline, and quote transparently every time.

Is it worth fixing an old Victoria Arduino machine that keeps throwing codes?

Depends on the machine, the code, and the cost. We give you honest math on this. If repairs are starting to exceed roughly 50% of a refurbished replacement and multiple major systems are throwing codes, we'll tell you it's time to look at replacing rather than running up the repair bill.

Will independent service void my Victoria Arduino warranty?

If your machine is under the manufacturer's warranty, independent service may affect coverage depending on Victoria Arduino's specific terms. Try the manufacturer's authorized network first. If their response is slow or they decline coverage for your code, call us and we'll service it on standard terms.

How many Victoria Arduino codes are documented on this page?

14 codes are documented above, organized by the system they affect. The list is compiled from manufacturer service literature, technician forums, and our own service log. We update it as new codes appear or firmware adds new states.

The record

Receipts from a quarter-century of service work.

"
We have a busy break room and the espresso machine matters to our team's morale. They keep it running like clockwork.
Eleanor · HR Director · Burlington Manufacturer
25+1
Years servicing equipment
4 hr2
Avg GTA response
92%3
First-visit resolution
4.74
Average client rating
1 Continuous service operations across the GTA since 2001. 2 Median on-site arrival window for urgent GTA calls placed during business hours. 3 Internal service tracking, 2024 to 2025 calendar years. 4 Calculated from verified client feedback over the past 24 months.

Stuck on a Victoria Arduino error code? Call a specialist.

We diagnose Victoria Arduino codes by phone routinely. Same-day on-site dispatch if it needs hands on the machine.

Call (289) 217-3796 now →
Call (289) 217-3796 Request Service