Filtered water with off-taste or noticeable chlorine
An exhausted filter cartridge, almost without exception. We fit a new cartridge, prime the line, reset the cycle counter, and taste-check the tap before we sign it off.
Still, sparkling, or stopped
Office water taps don't get sympathy; they're simply expected to work. When a TopWater pours flat sparkling, warm chilled, or nothing at all, we repair it at the cabinet: filter cartridges, CO2 supply and regulators, chiller faults, stuck solenoids. The usual suspects are consumables, the visit is short, and the tap goes back to being ignored, which is the point.
We'll get back to you today.
Thanks. We received your request.
A Grajqevci technician will get back to you today to confirm your machine and book the visit. If it's urgent, call us directly at (289) 217-3796.
Something went wrong sending your request.
Please try again, or call us directly at (289) 217-3796 and we'll book your service over the phone. You can also email [email protected].
TopBrewer · Under-counter filtered water tap
TopWater is the platform's water tap: filtered still, chilled, and sparkling from the same under-counter cabinet. It shares the design language and the service logic of the coffee systems, with a chiller, CO2 carbonation on sparkling models, and a filter doing the quiet work. Premium offices fit it beside a TopBrewer so the whole beverage wall is taps. In service terms it's wonderfully predictable: when something drifts, it's the filter or the CO2 far more often than the refrigeration.
Why Grajqevci
Call in the morning and a technician is usually on-site before the day is out. Most TopBrewer TopWater jobs get diagnosed and fixed on the first visit.
Commercial coffee equipment is all we do, and TopBrewer TopWater is part of the weekly rotation. Not a generalist guessing at a service manual. Genuine OEM parts, industry-standard procedures.
Flat rate for the visit, with parts billed separately. For bigger jobs you'll see a written quote on-site before we proceed.
Skip the wait
Trusted by Toronto's most demanding teams
TopWater faults we diagnose
Most TopWater calls trace to a short list of causes. Here's that list, with what's behind each fault and how we put it right.
An exhausted filter cartridge, almost without exception. We fit a new cartridge, prime the line, reset the cycle counter, and taste-check the tap before we sign it off.
An empty CO2 tank, a failed regulator, or a carbonation pump below spec. We check tank pressure and contents, test the regulator, and inspect the pump. A tank swap is quick; a pump that's genuinely done gets quoted before replacement.
A refrigeration fault, a dead fan, or a drifting thermostat. We measure the chiller output, verify refrigerant pressure, and inspect the fan and thermostat. Most cases land on the fan or thermostat; refrigerant work gets escalated when it's the real fault.
Scale on the element, a drifted thermostat, or an element failure. We descale the hot circuit, test the element's resistance, and replace it if scale has done permanent damage.
The counter needs a manual reset through the service interface after a cartridge change. We confirm the new cartridge is seated and primed, reset the counter, and verify the alert stays gone.
Worn nozzle seal or mineral deposit at the tip. We descale the tap, fit a new seal, and bleed the line.
A stuck dispense solenoid or a control board fault. We test the solenoid coil, replace it if it has failed, verify the control board signal, and confirm the dispense cuts off cleanly.
We connect through the Scanomat service interface beneath the counter, read the fault log, and pin the fault to filter, CO2, chiller, or electronics before fixing it at the root.
A failed power supply, a blown fuse, or a controller fault. We diagnose at the test points with a multimeter, replace the failed component, and bring the unit back up.
Network connectivity or cloud sync. We verify the local network, check the Scanomat cloud account, and re-pair the unit if the registration has drifted.
The same access challenge as TopBrewer: we free the cabinet path and quote remediation where the original fit-out needs opening up.
When changeovers come too often for the venue, the tank is undersized for the demand. We measure CO2 use against tank size, recommend a larger tank or bulk supply where the volume justifies it, and check the regulator is sized for the upgrade.
Leak-by from a worn valve seat. The solenoid gets replaced as an assembly, then we verify dry-tap operation across every dispense mode.
Your coffee emergency ends here
Call or submit the form. We confirm your address, model, and the issue.
An experienced technician arrives, runs full diagnostics, and identifies the root cause.
You receive a flat, itemized quote. Nothing proceeds without your green light.
We complete the repair, run a test cycle, and walk you through what to watch for.
Parts on the truck
What we've done
Our franchise machine has been quietly degrading for months. Their tech rebuilt the brew unit, recalibrated the grinder, and the espresso quality came back instantly.
*Estimated based on the approximate distance from our nearest service centre, average commute time, and median service-call length for one machine. Prices in Canadian dollars (CAD $). Final quote provided on-site after diagnosis.
FAQ
20 answers covering service, repair, parts, installation, warranty, and edge cases.
Updated July 2026
An exhausted filter cartridge, almost without exception. Replace it, prime the line, and reset the counter, and the taste comes back; if it doesn't, we descale the dispense path and check what's upstream. Offices on low volume often run cartridges past their date because nothing reminds them.
Either the CO2 tank has run down, the regulator output has drifted, or the carbonation pump is below spec. The tank is the usual answer and the quickest fix. We verify all three in one visit so you're not buying gas to mask a regulator fault.
Usually not. A failed fan or a drifting thermostat causes most warm-water complaints, and both are quick replacements. Genuine refrigerant work is rarer, and we tell you before that bill exists.
A stuck dispense solenoid or a control board fault. We test the solenoid coil, replace it if it's failed, and verify the board's signal so the tap cuts off cleanly every time.
The machine counts usage and raises the alert when the cartridge reaches its rated capacity, so the honest answer is: when it tells you. On moderate GTA water that lands every few months for a busy office tap. We log your interval and can put changes on a schedule so the alert never surprises anyone.
The whole system: tanks, regulators, carbonation pump, and the dispense valves downstream. If changeovers are coming too often we'll size the demand and recommend a larger tank or bulk supply rather than selling you more frequent visits.
The hot circuit does, and the dispense path benefits from it. Scale on the hot tap's element is the usual reason target temperature drifts. The chilled side mostly needs filtration kept honest rather than descaling.
Network connectivity or a drifted cloud registration, the same as the coffee systems. We verify the local network, check the cloud account, and re-pair the unit. If your building's firewall is the blocker, we work it through with IT.
Flat rate for the visit, parts billed at their actual cost on top. You'll hear the rate when you book, and for bigger jobs we quote in writing on-site before any work starts. No estimate that balloons mid-job.
Same-day in most cases. Call in the morning and a technician is usually on-site before the day is out; calls placed later in the day book for the next morning. Urgent breakdowns get priority routing.
The GTA and most of the Golden Horseshoe: Toronto through Mississauga, Vaughan, and Markham, out to Oshawa, Hamilton, and Niagara. If you're not sure you're in range, call and we'll tell you straight.
No. We work call by call. Plenty of customers put us on a maintenance schedule eventually, but that's their choice after seeing the work, never a requirement.
Parts carry their manufacturer warranty, and we stand behind our labour: if the same fault recurs, call us and we'll review it. Specific terms are discussed upfront on each job, not promised in marketing copy.
On-site whenever possible, which is most of the time. If a job genuinely needs the bench, like a full boiler rebuild or major electronics work, we'll say so before anything leaves your building.
Call us or send the form on this page. We confirm the machine, the fault, and a time window the same day. If it's urgent, say so and we'll route the nearest technician.
Diagnosis first: we confirm the fault, tell you what caused it, and quote the fix before touching a wrench. Most repairs finish in that same visit because the common wear parts ride on the truck.
High-wear parts for the platforms we service constantly ride on the truck. Anything else we order, usually next-day where suppliers allow, and we tell you the lead time before committing you to anything.
Usually, yes. We service legacy machines for as long as parts can be sourced, and we're honest when a repair stops making financial sense against a replacement. You get the math, you make the call.
Often, but that's not the pitch. We quote against the actual work, not a factory pricing book, and we'll tell you when a manufacturer warranty claim is the better route. Transparency is the value; the price usually follows.
Yes, and we do it by default on the way out. Half of repeat faults trace back to skipped daily cleaning or wrong routine, so the technician walks your team through what actually matters before leaving.
Most TopWater fixes are consumables; the visit is quick and quoted upfront.
Call (289) 217-3796 now →